Characteristic
– Class 5 according to PN-EN 303-5:2012
– Ecodesign
– High efficiency
– Automatic work
– Fast and easy operation
– Economical fuel combustion
– Smokeless and ecological combustion
– Ability to control the boiler’s operation via Internet (option)
– Possibility to install the fuel tank on the left or right side of flues
AQUA GOLD
The Aqua Gold model boilers with retort burner are intended for water open and closed system central heating installations (after installing a cooling coil with BVTS valve) with both gravitational and forced water circulation. The installation must be secured according to currently valid and detailed national provisions. Steel Aqua Gold model boilers with automatic fuel supply system are intended for work in central heating installations and domestic hot water preparation installations in housing development buildings, i.e. single family houses, commercial pavilions, garages, and utility buildings. Boilers constitute a steel structure welded from certified 6 mm thick boiler sheets that ensure a long-term use. The controller handles CH and DHW pumps, as well as auxiliary pump and valve actuator. There is a possibility to connect room regulator and SafeIT (control via Internet) module.
L.p | Specification | J.m | Information | |
1. | Boiler type | AQUA GOLD 25 | ||
2. | Nominal thermal power | kW | 25 | |
3. | Range of power for coal | kW | 7.5-25 | |
4. | Boiler class due to PN-EN 303-5:2012 | 5 | ||
5. | Size of heated surface | m² | <270 | |
6. | Capacity of the storage chamber Fuel | kg | 100 | |
7. | Combustion upon nominal power | h | 26/88 | |
8. | Efficiency | % | 88,89 | |
9. | Maximum working temperature (water supply) | ºC | 85 | |
10. | Minimum working temperature (return) | ºC | 55 | |
11. | Minimum working temperature | ºC | 10 | |
12. | Maximum permissible working pressure | MPa | 0,25 | |
13. | Flow resistance | at ΔT=10K | mbar | b.d |
at ΔT=20K | mbar | b.d | ||
14. | Maximum test pressure | MPa | 0,5 | |
15. | Mass of the boiler (±5%) | kg | 390 | |
16. | Exhaust fumes temperature Nominal power/min. | ºC | 167/88 | |
17. | Exhaust mass flow | g/s | 20,2/8,6 | |
18. | Required exhaust flow | Pa | 28 | |
19. | Cross-section of the chimney hole – minimum | cm² | 280 | |
20. | Power supply | V/Hz/A | 230 / 50 / 0,5-3,15 | |
21. | Power consumption | W | 180 | |
22. | Water capacity of the boiler | L | 90 | |
23. | Fuel | Black coal sort of pea, granulation 5-25mm | ||
24. | Required capacity of the heat accumulator Qmin>0,3QN | L | 500 | |
25. | Minimum chimney height | m | 7 | |
26. | Exchanger surface area | m² | 2,4 | |
27. | Diameter of the flue | mm | Ø178 | |
28. | Water supply connector/return | cal | 1 1/2 | |
29. | Emission of noise | dB | >60 | |
30. | Dimension | A | mm | 612 |
B | mm | 872 | ||
C | mm | 160 | ||
D | mm | 1351 | ||
E | mm | 1076 | ||
F | mm | 178 | ||
G | mm | 1183 | ||
H | mm | 1556 | ||
I | mm | 552 |