    The Szulce model boilers are intended for water open system central heating installations with both gravitational and forced water circulation. The installation must be secured according to currently valid and detailed national provisions. Steel Szulce model boilers with automatic fuel supply system are intended for work in central heating installations and domestic hot water preparation installations in housing development buildings, i.e. single family houses, commercial pavilions, garages, and utility buildings. Boilers constitute a steel structure welded from certified 6 mm thick boiler sheets that ensure a long-term use. The controller handles CH and DHW pumps, as well as auxiliary pump and valve actuator. There is a possibility to connect room regulator and SafeIT (control via Internet) module.

    L.pSpecificationJ.mInformation
    1.Boiler typeSzulce 12Szulce 18Szulce 24
    2.Nominal thermal powerkW121824
    3.Range of power for coalkW3,6-125,4-187,2-24
    4.Size of heated surfaceup to 150up to 180up to 250
    5.Capacity of the storage chamber Fuell74126168
    6.Combustion upon nominal powerh46/16140/14035/120
    7.Boiler class due to PN-EN 303-55
    8.Efficiency%89,5689,888,83
    9.Maximum working temperature (water supply)°C80
    10,Temp. of water in the supply min./max°C55/80
    11.Minimum working temperature (return)°C50
    12.Minimum working temperature°C10
    13.Exhaust fumes temperature Nominal power/min.°C119/62115/61115/78
    14.Exhaust mass flowg/s7,8/2,810,6/3,815,2/7,8
    15.Required capacity of the heat accumulator Qmin>0,3QNL240360480
    16.Emission of noisedB>60
    17.Maximum permissible working pressurebar1,5
    18.Flow resistanceat ΔT=10Kmbarb.d.
    at ΔT=20Kmbarb.d
    19.FuelBlack coal sort of pea, granulation 5-25mm
    20.Mass of the boiler (±5%)kg255307356
    21.Required exhaust flowmbar0,250,260,26
    22.Minimum chimney heightm6
    23.Cross-section of the chimney hole – minimumcm²220230294
    24.ZasilanieV/Hz/A∼230/50/0,55÷3,15
    25.Power supplyW≥122≥162≥162
    26.Water capacity of the boilerL67,57591
    27.Exchanger surface area1,732,262,78
    28.Diameter of the fluemmØ158
    29.Water supply connector/returncal1
    30DimensionAmm472
    Bmm620
    Cmm115811581158
    Dmm109612651489
    Emm107612431468
    Fmm112112881513
    Gmm588
    Hmm120

     

    Others in the category Eco-pea coal boilers

    Central heating boilers

    INTEGRA

    Central heating boilers

    KRS TECH DUO +

    Central heating boilers

    AQUA GOLD

    Central heating boilers

    POSEJDON

    Central heating boilers

    ELZA

    Central heating boilers

    PRADO

    Central heating boilers

    INTER-TECH