Characteristic
– Class 5 according to PN-EN 303-5:2012
– Ecodesign
– Low fuel consumption
– Modern and compact design
– Automatic work
– Economical fuel combustion
– Electronic controller
– Innovative burner self-cleaning system
– Automatic firing up
– Ability to control the boiler’s operation via Internet (option)
– Possibility to install the fuel tank on the left or right side of flues
PELL-DUO +
The Pell-Duo+ model boilers are intended for water open system central heating installations with both gravitational and forced water circulation. The installation must be secured according to currently valid and detailed national provisions. Steel Pell-Duo+ model boilers with automatic fuel supply system are intended for work in central heating installations and domestic hot water preparation installations in housing development buildings, i.e. single family houses, commercial pavilions, garages, and utility buildings. Pell-Duo+ models are compact pellet boilers with automated kindling and extinguishing. They have been equipped with self-cleaning burner made from heat-resistant steel. In vertical exchanger was used an innovative solution, namely a clean-out ash compartment that insulates the boiler’s bottom, which significantly improves the heating efficiency of boilers. The boiler’s controller is a device made from highly advanced technology adapted to handling energy-saving electronic pumps. The controller handles CH and DHW pumps, as well as valve actuator. There is a possibility to connect room regulator and SafeIT (control via Internet) module.
L.p | Specification | J.m | Information | ||||
1. | Boiler type | Pell-Duo+ 14 | Pell-Duo+ 18 | Pell-Duo+ 22 | Pel-Duo+ 28 | ||
2. | Nominal thermal power | kW | 14 | 18 | 22 | 28 | |
3. | Size of heated surface | m² | up to 140 | up to 180 | up to 220 | up to 280 | |
4. | Boiler class due to PN-EN 303-5:2012 | 5 | |||||
5. | Capacity of the storage chamber Fuel | l | 140 | 140 | 147 | 200 | |
6. | Combustion upon nominal power | h | 27/92 | 21/73 | 20/72 | 19/66 | |
7. | Efficiency | % | 61,6 | 91 | 90,,8 | 90,8 | |
8. | Maximum working temperature (water supply) | ºC | 85 | ||||
9. | Temp. supply water min./max. | ºC | 55/80 | ||||
10. | Minimum working temperature (return) | ºC | 50 | ||||
11. | Minimum working temperature | ºC | 10 | ||||
12. | Minimum working temperature | ºC | 112/72 | 103/73 | 127/97 | 144/115 | |
13. | Exhaust mass flow nom./min | g/s | 9,8/3,8 | 13,3/4,9 | 15,2/5,9 | 18/8 | |
14. | Required capacity of the heat accumulator Qmin>0,3QN | L | 280 | 360 | 440 | 560 | |
15. | Emission of noise | dB | >60 | ||||
16. | Maximum permissible working pressure | bar | 1,5 | ||||
17. | Test pressure | bar | 3 | ||||
18. | Flow resistance | at ΔT=10K | mbar | b.d | |||
at ΔT=20K | mbar | b.d | |||||
19. | Fuel | Pellet drzewny o średnicy 6-8 mm | |||||
20. | Mass of the boiler (±5%) | kg | 247 | 308 | 235 | 348 | |
21. | Required exhaust flow | mbar | 0,23 | 0,25 | 0,27 | 0,29 | |
22. | Minimum chimney height | m | 6 | 6 | 7 | 7 | |
23. | Cross-section of the chimney hole – minimum | cm² | 171 | 190 | 215 | 273 | |
24. | Power supply | V/Hz/A | 230 / 50 / 0,5 ÷ 3,15 | ||||
25. | Power consumption start/work | W | ≥356 /≥56 | ||||
26. | Water capacity of the boiler | L | 58 | 71 | 78 | 86 | |
27. | Exchanger surface area | m² | 2 | 2,5 | 2,8 | 3,3 | |
28. | Diameter of the flue | Ømm | 128 | 158 | 158 | 178 | |
29. | Water supply connector/return | cal | 1 1/2″ | ||||
30. | Drain plug | cal | 1/2″ | ||||
31. | Dimension | A | mm | 774 | |||
B | mm | 1170 | |||||
C | mm | 202 | |||||
D | mm | 895 | 1068 | 1162 | 1262 | ||
E | mm | 636 | 779 | 873 | 953 | ||
L | mm | 1038 | 1038 | 1132 | 1232 | ||
G | mm | 925 | |||||
H | mm | 975 | 1148 | 1242 | 1342 | ||
K | mm | 460 | |||||
J | mm | 130 |